What Does TDP Mean and What Does It Say About Power Use?

What TDP means, what it does not tell you and how to use it when choosing hardware.

Blog5 min read

Short answer

TDP (thermal design power) is a design value that manufacturers specify for cooling and power supply. It is not measured power consumption and is not defined in the same way by every manufacturer. Use it to size cooling and power supply, and look at measurements under your own workload for real power use.

What is TDP?

TDP roughly indicates how much heat the cooling system must be able to remove under a particular load chosen by the manufacturer. Some manufacturers also quote other values, such as a base power and a higher peak value. For graphics cards, manufacturers often speak of board power or total graphics power.

What does TDP not tell you?

Why does it matter anyway?

For cooling, power supply and the space in a cabinet or rack. A server with many GPUs needs a lot of power and cooling. In a data centre, electricity is also a cost item and a capacity limit: see our post on the power consumption of data centres.

How to use TDP when choosing

For a server, add up the TDP values of the processor and GPUs, add headroom for other components and allow for peaks above the TDP. Choose a power supply with sufficient margin and check that the cooling can remove the heat. For a cabinet or rack, airflow is also important.

If you want to know the real power use, measure it under your own workload with an energy meter or the server’s management interface. That gives a better picture than the specification alone.

What are the power values called at Intel, AMD and NVIDIA?

Manufacturers use different names for what at first glance seems to be the same value. This table helps you read a specification sheet.

TermWhat it usually refers toWhere you see it
TDPDesign value for cooling; the precise definition differs per manufacturerFor example as ‘Default TDP’ on AMD product pages
Processor Base PowerIntel’s name for the value that used to be called TDP (from the 12th generation of Core)Intel specification pages
Maximum Turbo PowerHigher power that an Intel processor can use for a limited timeIntel specification pages
PPTAt AMD, the limit for the total power of the processor in the socket, higher than the TDPAMD motherboard and processor information
TGP or TBPPower for the whole graphics card (NVIDIA: Total Graphics Power, AMD: Total Board Power)Graphics card specifications

Intel itself writes that power can temporarily exceed the TDP during turbo or heavy instructions. NVIDIA explains that TDP and TGP are based on a demanding application, and so not on light everyday use. So read the name of the value, not only the number in watts.

How do you work out the power you need for your power supply?

An example using your own numbers. Fill in the values of the parts you have or are considering:

  1. For the processor, note the highest stated power (Maximum Turbo Power or PPT), not only the TDP.
  2. For the graphics card, note the manufacturer’s TGP or TBP.
  3. Include the drives. Hard drives use more current when starting up than when running. Seagate lists a separate start-up current (spin-up) on 12 volts in its manuals. Current in amperes × 12 volts gives the power in watts.
  4. Add the motherboard, memory, fans and expansion cards.
  5. Add everything up and choose a power supply whose stated power is comfortably above that.

Also check whether the power supply has enough connectors for your drives and graphics card. For a server without a graphics card, the processor is often the biggest item; see also which processor for a NAS.

What misunderstandings exist about TDP?

How do you measure the real consumption of your computer or server yourself?

A specification remains an estimate. Measuring takes little effort:

  1. Place an energy meter between the wall socket and the power supply’s plug.
  2. Note the consumption at idle (after start-up, drives not active).
  3. Note the consumption during the task you really do, for example a backup or converting video.
  4. Also note the peak at start-up.

Keep in mind that the meter shows more than the parts draw, because the power supply itself also has losses. With the formula kWh = watts × hours ÷ 1000 you convert the consumption to a period, for example a year, and can compare it with your energy bill.

Frequently asked questions

Is a lower TDP more economical?

Not necessarily. TDP says something about the heat the cooling has to remove, not directly about efficiency. A chip with a higher TDP can still do more work per watt.

Can a CPU use more than its TDP?

Yes. Many processors may use more power than the TDP for short periods, and sometimes for longer. Manufacturers quote separate values for this (for AMD, for example, PPT; for Intel, Processor Base Power and Maximum Turbo Power). How long this is allowed also depends partly on the motherboard.

What is the difference between TDP and TGP?

TDP is usually a design value for cooling. TGP (at NVIDIA) or TBP (at AMD) refers to the power that the whole graphics card needs. NVIDIA calls TGP the power that the power supply must be able to deliver to the graphics subsystem.